PRODUCTS

VIS-G29

A microprocessor control for the regulation of the viscosity of the water base ink and solvent base happens thanks to a vibration sensor and it is possible to integrate the pH control system.

APPLICATIONS

OVERVIEW

The VIS-G29 is a system for the regulation of the viscosity of inks based on water and solvent. The measurement of the viscosity takes place thanks to a vibration sensor immersed in the liquid to be analyzed, without moving parts.
It, in series with the flow, emits a frequency that in contact with the liquid is changed, may alternatively also be installed in derivation to the ink flow.
From the analysis extrapolates the viscosity in seconds (cup ZAHN, FORD, …) and by the correction valve maintains the management based on the reference set. The cleaning of the viscometer performed at the end of work, at the same time washing the inking circuit.

APPLICATIONS

3D Application Isometric View

Detail 3D Application

TECHNICAL DETAILS

DISPLAY PANEL AND MANAGEMENT

  • PC with 15 '' / 17 '' / 21 '' touchscreen;
  • Visualization of all colors monitored on a single screen;
  • Display of viscosity via bar graphs;
  • Choosing the type of reference cup, setting the reference viscosity;
  • Saving up to 5000 different jobs;
  • Compensation of ink temperature;
  • Error Reporting by using graphical indicators (no ink or solvent or viscosity out of tolerance).

CONTROL G29-VID

  • New generations of electronic components and high reliability;
  • The electronic component is marked II (1) G [Ex ia] IIB to be installed in the safe area;
  • Cabinet installation chosen by the client;
  • Serial communication between interface and control.

OPTION SINGLE CONTROL G29

  • HMI touch screen display 4.3 '' or 9.7 ''.

DETECTOR RIV-VXR-G29

  • The G29 can be positioned in hazardous area in series with the ink flow or shunt;
  • The G29 marking II 2G Ex ib IIB T5 Gb;
  • Solvent correction via pneumatic valve, the solenoid valve can be marked II 2G Ex ia IIB T6;
  • Ink supply with electric or pneumatic pump;
  • Viscosity measurement with a resolution of 1%.

ADDITIONAL OPTIONS

  • System for control the ink temperature, via a heat exchanger with high efficiency.
  • System for control the pH, via a pH probe dedicated.

MAINTENANCE AND CLEANING

  • No maintenance required;
  • After work by cleaning inking system also cleans the viscometer;
  • No mechanical element subject to usury